SW2600 Sloped Wall System Specifications |
|
General |
Windows to be manufactured by Lynbrook Glass, Hauppauge, NY. Series No. SW2600 Slope Wall or equal. Framing members shall be neatly mitered and/or butt joined and sealed. Corners shall be mechanically fastened, and/or hydraulically crimped.
|
Framing Members |
To be 2-1/2” sight line x 6-1/4 ” deep (or deeper)
Wall thickness to be .125 minimum
|
Thermal Barrier Ventilators |
To be of tubular construction mitered and hydraulically crimped – all joints to be sealed – entire frame to be double sealed at interior and exterior with appropriate gaskets to maintain performance requirements. |
|
Performance Rating |
Air Infiltration to .009 C.F.M./Ft.² at 6.24 P.S.F.
Water Resistance to 15 P.S.F. No entry.
Uniform Load Deflection: Not to exceed L/175
C.R.F. (Condensation Resistance Factor): 61
|